;║ Token ring Network 16/4 Adapter II ║
;║ Adapter Configuration File Version 1.00 ║
;║ ║
;╚═════════════════════════════════════════════════════════════════╝
BOARD
ID = "OEM5120"
NAME = "Token ring Network 16/4 Adapter II"
MFR = "OEM"
CATEGORY = "NET"
SLOT = ISA16
LENGTH = 285
AMPERAGE = 700
SKIRT = NO
READID = NO
BUSMASTER = 1
IOCHECK = INVALID
DISABLE = UNSUPPORTED
COMMENTS = "\nThe Token ring Network 16/4 Adapter II
is designed for use in ISA and EISA bus computers.\n\n
The EISA configuration utility will identify a conflict-
free configuration of system resources and suggest
switch settings for the adapter. Prior to exiting the
utility, record the suggested switch settings, then exit
and set switches manually on the adapter before continuing
any Token ring 16/4 Adapter II operation.\n
NOTE: To activate a change of the switch settings
a power ON/OFF cycle must be executed"
SWITCH(1) = 12
NAME = "SW1 Configuration Switch"
STYPE = DIP
VERTICAL = YES
REVERSE = YES
LABEL = LOC(1-12) "1" "2" "3" "4" "5" "6" "7" "8" "9" "10" "11" "12"
FACTORY = LOC(1-12) 111111111111
COMMENTS = "\nSwitch Block SW1 is an 12-position configuration DIP-switch
used to set the IO address / interrupt level / DMA channel /
Ring Speed / Cable Type and to enable Remote Program Load.
Three positions of SW1 (1-3) are used to set the ROM address /
IO address and the remaining nine positions are used to set the
interrupt level , DMA level , Ring Speed.\n
Please refer to the Token ring Network 16/4 Adapter II
Installation Guide for further details on switch
settings."
FUNCTION = "Token ring Network 16/4 Adapter II"
TYPE = "NET,TOK"
CONNECTION = "8-Pin RJ45 and 9-Pin D-Connector"
SUBFUNCTION = "IO Base Address, RPL Setting"
COMMENTS = "The factory default IO Base address location for the adapter
is 86A0 and can vary from 86A0 to F6A0. The selected
IO Base address must also be set in the Protocol.Ini file
used by the software.
The REMOTE PROGRAM LOAD function will be enabled via the
card switch number 8."
CHOICE = "86A0,RPL Disabled"
LINK
PORT = 086A0h-086AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 111
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "86A0,RPL Enabled"
LINK
PORT = 086A0h-086AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 111
LINK
INIT = SWITCH(1) LOC(1-3) 111
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
MEMORY = 16K
ADDRESS = 0C0000h
WRITABLE = NO
SIZE = BYTE
CHOICE = "96A0,RPL Disabled"
LINK
PORT = 096A0h-096AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 011
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "96A0,RPL Enabled"
LINK
PORT = 096A0h-096AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 011
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
LINK
INIT = SWITCH(1) LOC(1-3) 011
MEMORY = 16K
ADDRESS = 0C4000h
WRITABLE = NO
SIZE = BYTE
CHOICE = "A6A0,RPL Disabled"
LINK
PORT = 0A6A0h-0A6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 101
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "A6A0,RPL Enabled"
LINK
PORT = 0A6A0h-0A6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 101
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
LINK
INIT = SWITCH(1) LOC(1-3) 101
MEMORY = 16K
ADDRESS = 0C8000h
WRITABLE = NO
SIZE = BYTE
CHOICE = "B6A0,RPL Disabled"
LINK
PORT = 0B6A0h-0B6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 001
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "B6A0,RPL Enabled"
LINK
PORT = 0B6A0h-0B6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 001
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
LINK
INIT = SWITCH(1) LOC(1-3) 001
MEMORY = 16K
ADDRESS = 0CC000h
WRITABLE = NO
SIZE = BYTE
CHOICE = "C6A0,RPL Disabled"
LINK
PORT = 0C6A0h-0C6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 110
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "C6A0,RPL Enabled"
LINK
PORT = 0C6A0h-0C6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 110
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
LINK
INIT = SWITCH(1) LOC(1-3) 110
MEMORY = 16K
ADDRESS = 0D0000h
WRITABLE = NO
SIZE = BYTE
CHOICE = "D6A0,RPL Disabled"
LINK
PORT = 0D6A0h-0D6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 010
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "D6A0,RPL Enabled"
LINK
PORT = 0D6A0h-0D6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 010
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
LINK
INIT = SWITCH(1) LOC(1-3) 010
MEMORY = 16K
ADDRESS = 0D4000h
WRITABLE = NO
SIZE = BYTE
CHOICE = "E6A0,RPL Disabled"
LINK
PORT = 0E6A0h-0E6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 100
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "E6A0,RPL Enabled"
LINK
PORT = 0E6A0h-0E6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 100
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
LINK
INIT = SWITCH(1) LOC(1-3) 100
MEMORY = 16K
ADDRESS = 0D8000h
WRITABLE = NO
SIZE = BYTE
CHOICE = "F6A0,RPL Disabled"
LINK
PORT = 0F6A0h-0F6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 000
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 1
CHOICE = "F6A0,RPL Enabled"
LINK
PORT = 0F6A0h-0F6AFh
SHARE = NO
SIZE = BYTE
INIT = SWITCH(1) LOC(1-3) 000
INIT = SWITCH(1) LOC(6-7) 11
INIT = SWITCH(1) LOC(8) 0
LINK
INIT = SWITCH(1) LOC(1-3) 000
MEMORY = 16K
ADDRESS = 0DC000h
WRITABLE = NO
SIZE = BYTE
SUBFUNCTION = "Interrupt Level"
TYPE = "INT"
COMMENTS = "The Token ring Network 16/4 Adapter II
can operate on one of four interrupt levels: 9 ,10 , 10
and 15. The factory default interrupt level is 9."
CHOICE = "Interrupt 9"
SUBTYPE = "9"
LINK
IRQ = 9
SHARE = NO
TRIGGER = EDGE
INIT = SWITCH(1) LOC(4 5) 11
CHOICE = "Interrupt 10"
SUBTYPE = "10"
LINK
IRQ = 10
SHARE = NO
TRIGGER = EDGE
INIT = SWITCH(1) LOC(4 5) 01
CHOICE = "Interrupt 11"
SUBTYPE = "11"
LINK
IRQ = 11
SHARE = NO
TRIGGER = EDGE
INIT = SWITCH(1) LOC(4 5) 10
CHOICE = "Interrupt 15"
SUBTYPE = "15"
LINK
IRQ = 15
SHARE = NO
TRIGGER = EDGE
INIT = SWITCH(1) LOC(4 5) 00
SUBFUNCTION = "DMA Level"
COMMENTS = "\nUp to three Token ring Network 16/4 Adapter II
may be installed within a single computer. When
multiple adapters are being installed in a single computer,
each adapter must be assigned to a different DMA channel.
Select the appropriate function within the EISA
Configuration Utility to display the switch setting(s)."
CHOICE = "DMA 5"
LINK
DMA = 5
SHARE = NO
INIT = SWITCH(1) LOC(9 10) 11
CHOICE = "DMA 6"
LINK
DMA = 6
SHARE = NO
INIT = SWITCH(1) LOC(9 10) 01
CHOICE = "DMA 7"
LINK
DMA = 7
SHARE = NO
INIT = SWITCH(1) LOC(9 10) 00
SUBFUNCTION = "Adapter Ring Speed"
TYPE = "SPD"
COMMENTS = "\nThe Token ring Network 16/4 Adapter II
can operate at either 4 or 16 Mbps ring speed. The adapter
ring speed MUST match the Token ring Network.\n
Select the appropriate function within the EISA
Configuration Utility to display the switch setting(s)."
CHOICE = "4 Mbps"
SUBTYPE = "4"
FREE
INIT = SWITCH(1) LOC(11) 1
CHOICE = "16 Mbps"
SUBTYPE = "16"
FREE
INIT = SWITCH(1) LOC(11) 0
SUBFUNCTION = "Cable Type"
TYPE = "SPD"
COMMENTS = "\nThe Token ring Network 16/4 Adapter II
can operate either using Shielded Twisted Pair cable or
Unshielded Twisted Pair cable .\n
Select the appropriate function within the EISA
Configuration Utility to display the switch setting(s)."
CHOICE = "STP Type"
SUBTYPE = "STP"
FREE
INIT = SWITCH(1) LOC(12) 1
CHOICE = "UTP Type"
SUBTYPE = "UTP"
FREE
INIT = SWITCH(1) LOC(12) 0